STAT FMD
display text: Status of the specified Fixed Media
Device
command parameter: core # with values of 0 or 1
STAT RMD
display text: Status of both Removable Media Devices
(RMD)
command parameter: none
STAT RMD
display text: Status of the specified Removable Media
Device
command parameter: "core #" with values of 0 or 1
At this point, it is possible to customize the HSP IP addresses on the HSP
ports. To do this, change the HSP addresses on the active side, and the
addresses are automatically invoked on the inactive side.
For more information, see Communication Server 1000: System Redundancy
(553-3001-307).
Testing the Call Servers
Procedure 29
Testing Call Server 0
At this point in the installation, Call Server 0 is tested from active Call Server 1.
Upon successful completion of these tests, call processing is switched and the
same tests are performed on Call Server 1 from active Call Server 0. As a final
step, call processing is then switched again to Call Server 1.