If the system cannot communicate with a 10BASE-T network, the Ethernet link test
setting for the port may be incompatible with the setting at the network hub. See
Section 9.6.1 "Failure of Network Communications," for further details.
9.5.3.3
probe-scsi-all Command
The probe-scsi command locates and tests SCSI devices attached to the system.
probe-scsi is run from the OpenBoot prompt.
When it is not practical to halt the system, you can use SunVTS as an alternate
method of testing the SCSI interfaces.
9.5.3.4
probe-fcal-all Command
The probe-fcal-all command locates and tests fibre channel devices attached to
the system. probe-fcal-all is run from the OpenBoot prompt. This command
could take longer to complete if one or more of the Fibre Channel Arbitrated Loops
are unconnected.
When it is not practical to halt the system, you can use SunVTS as an alternate
method of testing the fibre channel interfaces.
9.5.3.5
Reference Documents for POST/OpenBoot
OpenBoot 3.x Command Reference, part number 802-3242
Writing FCode 3.x Programs, part number 802-3230
9.5.4

Sun Management Center

The Sun Management Center program monitors system functioning and features a
graphical user interface (GUI) to continuously display system status. Sun
Management Center is intended to complement system management tools such as
SunVTS.
Sun Management Center is accessible through an SNMP interface from network
tools such as Solstice SunNet Manager™.
Refer to the Sun Management Center User's Guide manual, part number 802-5355, for
starting and operating instructions.
Chapter 9
Troubleshooting Overview
9-11