10.5

Defective Disk Drive

Begin
INDICATION
System error message or
device code identifies a
specific fault
Device not identified or
intermittent problem
End
FIGURE 10-5
10-6
Sun Enterprise 3500 System Reference Manual • August 2001
TEST/PROCEDURE
Check system messages to
locate failed drive.
Halt access to device and power
down the device or tray.
Set ID code (if used) on
replacement device before
installing.
If replaced unit is
SPARCstorage™ Array
disk tray or the tray
controller board, reset
world-wide name (WWN).
Run SunVTS.
Check cable connection.
If replaced unit is SPARCstorage
Array disk tray or the tray
controller board, reset
world-wide name (WWN).
Diagnosing Disk Drive Problems
REFERENCE
Internal drives: Chapter 7. For
tray, see tray service
manual.
See
, or refer to
TABLE C-2
drive or tray
documentation for ID
code.
Refer to SPARCstorage Array
documentation.
Refer to the SunVTS User's
Guide.