Warning Messages - RMG USM GT400 Operating Manual

Ultrasonic flowmeter
Hide thumbs Also See for USM GT400:
Table of Contents

Advertisement

12 Alarm and warning messages
No. Message
32
Path 3 failure
33
Path 4 failure
34
Path 5 failure
172
35
Path 6 failure
36
Path 7 failure
37
Path 8 failure
38
max. path
40
Replacement
value not cal.
41
USE09 Timeout
42
ADC
temperature
43
ADC pressure
45
I1 Out min/max
47
Temp. min/max
48
Pressure
min/max
50
DSP path 1
51
DSP path 2
52
DSP path 3
53
DSP path 4
54
DSP path 5
55
DSP path 6
56
DSP path 7
57
DSP path 8
60
P1 AGC limit
61
P2 AGC limit
62
P3 AGC limit
63
P4 AGC limit
64
P5 AGC limit
65
P6 AGC limit
66
P7 AGC limit
67
P8 AGC limit
77
QVb min.
Grenze
78
QVb max. limit
99
Wrong Parm.

12.2 Warning messages

No.
Messages
100
Path1 Warn.
Manual USM GT400 · EN10 · May 2021
Explanation
Measuring path 3 failed
Measuring path 4 failed
Measuring path 5 failed
Measuring path 6 failed
Measuring path 7 failed (spare)
Measuring path 8 failed (spare)
Maximum permissible number of path failures exceeded
Replacement value for failed path could not be calculated
No valid measurement, all measuring paths have failed.
ADCfault temperature input
ADC fault pressure input
Power outlet outside the min. / max. limits
Temperature outside the min. / max. limits
Pressure outside the min. / max. limits
Critical path error. Error bits can be read-off separately in Path 1 error
Critical path error. Error bits can be read-off separately in Path 2 error
Critical path error. Error bits can be read-off separately in Path 3 error
Critical path error. Error bits can be read-off separately in Path 4 error
Critical path error. Error bits can be read-off separately in Path 5error
Critical path error. Error bits can be read-off separately in Path 6 error
Critical path error. Error bits can be read-off separately in Path 7 error
(spare)
Critical path error. Error bits can be read-off separately in Path 8 error
(spare)
Amplification factor for path 1 outside the permissible limits
Amplification factor for path 2 outside the permissible limits
Amplification factor for path 3 outside the permissible limits
Amplification factor for path 4 outside the permissible limits
Amplification factor for path 5 outside the permissible limits
Amplification factor for path 6 outside the permissible limits
Amplification factor for path 7 outside the permissible limits (spare)
Amplification factor for path 8 outside the permissible limits (spare)
Operating volume flow below Qmin
Operating volume flow above Qmax
Parameter entered is invalid
Explanation
Proportion invalid measurements for path 1 too high

Advertisement

Table of Contents
loading

Table of Contents