RMG USM GT400 Operating Manual page 242

Ultrasonic flowmeter
Hide thumbs Also See for USM GT400:
Table of Contents

Advertisement

15 Lists of parameters and measured values
Path7 Parameters
Coord. Value
AQ-09 p7 f-trans set val
234
AQ-10 path-7 trans. freq.
AQ-11 path-7 band limits
AQ-12 path-7
trans.pulses
AQ-13 p7 filter selection
AQ-14 path-7 tw
AQ-16 path-7 DAC-G1
cmd
AQ-17 path-7 DAC-G1 val
AQ-18 path-7 DAC-G2
cmd
AQ-19 path-7 DAC-G2 val
AQ-20 p7 blanking delay
AQ-21 p7 blanking count
AQ-22 path-7 decay time
AQ-23 path-7 path
length
AQ-24 path-7 axial dist.
AQ-25 p7 assembly an-
gle
AQ-26 p7 delta-t offset
AQ-29 const w7
AQ-30 p7 tic offset
AQ-31 p7 tic offset (X)
AQ-32 p7 AGC-limit
AQ-34 p7 no. of f-
batches
Manual USM GT400 · EN10 · May 2021
Reg.
No.
Type Prot. Unit
2512
2 L
S
Hz
2532
2 L
R
Hz
2196
1 I
S
%
2046
1 I
S
2176
1 M
S
kHz
1092
2 F
S
us
2056
1 I
S
2066
1 I
S
2076
1 I
S
2086
1 I
S
1112
2 F
R
us
2552
2 L
R
tic
1132
2 F
S
ms
1152
2 F
S
→ Calib. units:
1172
2 F
S
→ Calib. units:
1512
2 F
S
°
1432
2 F
S
us
1252
2 F
S
[1]
2206
1 I
S
tic
2266
1 I
S
tic
2226
1 I
S
dB
2318
1 I
C
Description
Path 7 transmit frequency intended
value in Hz
Path 7 transmit frequency actual value
in Hz
Path 7 limits to observe
Path 7 number of transmit pulses
Path 7 DSP filter selection
0x0000
0x0001
0x0002
0x0003
0x0004
0x0005
0x0006
0x0007
0x0008
0x0009
0x000a
0x000b
Path 7 delay time
Path 7 DAC-G1 command register
Path 7 DAC-G1 data register
Path 7 DAC-G2 command register
Path 7 DAC-G2 data register
Path 7 blanking delay
Path 7 blanking count
Path 7 pulse decay time
Length Path 7 path length
Length Path 7 smallest path distance
Path 7 assembly angle
Path 7 time difference offset
Path 7 weigthing factor w7
Path 7 tic offset
Path 7 tic offset (3X-measurement)
Path 7 AGC limit
Path 7 no. of measurement (FBatches)
50
75
100 (d)
125
150
175
200
225
250
275
300
325

Advertisement

Table of Contents
loading

Table of Contents