8 Installation
100
The bolted connection of Inlet (1) and outlet piping (3) must be tightened according
to the tightening torque of the plant manufacturer. The tightening torque must com-
ply with the bolts and seals used.
1
Clean the sealing surface of the flange from contamination with a gentle
cleaning agent.
2
Tighten the bolts crosswise in order to avoid tensioning.
Notice
In general, only the horizontal installation of the USM GT400 is strongly
recommended. Turning the meter by more than 2 flange holes should not be
used to avoid the collection of condensates in the sensor pockets. Only in dry
and clean gas, other installation positions might be possible also, but it is not
recommendable.
Manual USM GT400 · EN10 · May 2021
1
Inlet piping
2
Ultrasonic gas meter
3
Outlet piping
Fig. 8.2: Installation of the Inlet and outlet piping