Path8 Parameters
Coord. Value
Reg.
AR-09
p8 f-trans set val
2514
AR-10
path-8 trans. freq.
2534
AR-11
path-8 band limits
2197
AR-12
path-8
2047
trans.pulses
AR-13
p8 filter selection
2177
AR-14
path-8 tw
1094
AR-16
path-8 DAC-G1
2057
cmd
AR-17
path-8 DAC-G1 val
2067
AR-18
path-8 DAC-G2
2077
cmd
AR-19
path-8 DAC-G2 val
2087
AR-20
p8 blanking delay
1114
AR-21
p8 blanking count
2554
AR-22
path-8 decay time
1134
AR-23
path-8 path
1154
length
AR-24
path-8 axial dist.
1174
AR-25
p8 assembly an-
1514
gle
AR-26
p8 delta-t offset
1434
AR-29
const w8
1254
AR-30
p8 tic offset
2207
AR-31
p8 tic offset (X)
2267
AR-32
p8 AGC-limit
2227
AR-34
p8 no. of f-
2319
batches
15 Lists of parameters and measured values
No.
Type Prot. Unit
2 L
S
Hz
2 L
R
Hz
1 I
S
%
1 I
S
1 M
S
kHz
2 F
S
us
1 I
S
1 I
S
1 I
S
1 I
S
2 F
R
us
2 L
R
tic
2 F
S
ms
2 F
S
→ Calib. units:
2 F
S
→ Calib. units:
2 F
S
°
2 F
S
us
2 F
S
[1]
1 I
S
tic
1 I
S
tic
1 I
S
dB
1 I
C
Description
Path 8 transmit frequency intended
value in Hz
Path 8 transmit frequency actual value
in Hz
Path 8 limits to observe
Path 8 number of transmit pulses
Path 8 DSP filter selection
0x0000
0x0001
0x0002
0x0003
0x0004
0x0005
0x0006
0x0007
0x0008
0x0009
0x000a
0x000b
Path 8 delay time
Path 8 DAC-G1 command register
Path 8 DAC-G1 data register
Path 8 DAC-G2 command register
Path 8 DAC-G2 data register
Path 8 blanking delay
Path 8 blanking count
Path 8 pulse decay time
Length Path 8 path length
Length Path 8 smallest path distance
Path 8 assembly angle
Path 8 time difference offset
Path 8 weigthing factor w8
Path 8 tic offset
Path 8 tic offset (3X-measurement)
Path 8 AGC limit
Path 8 no. of measurement (FBatches)
Manual USM GT400 · EN10 · May 2021
235
50
75
100 (d)
125
150
175
200
225
250
275
300
325