RMG USM GT400 Operating Manual page 235

Ultrasonic flowmeter
Hide thumbs Also See for USM GT400:
Table of Contents

Advertisement

AI-22
amp. regulator
2146
min
AI-23
amp. regulator
2147
max
AI-24
amp. damping
1448
AI-25
theoretical SoS
1368
AI-26
ADC gain
2164
AI-27
signal tracking
2169
AI-28
max. track. Offset
2187
AI-37
corr. mode
2256
AI-38
corr. length
2189
AI-39
Batch: amp. min.
2279
AI-47
AmplitudeMin
2000
AI-48
AmplitudeMax
2010
AI-49
Vmin
1000
AI-50
Vmax
1020
AI-51
Cmin
1040
AI-52
Cmax
1060
DSP Parameters 3X
Coord. Value
Reg.
AJ-07
corr. mode (X)
2257
AJ-09
Batch: amp. min.
2280
15 Lists of parameters and measured values
1 I
C
%
1 I
C
%
2 F
C
2 F
S
→ velocity unit
1 M
S
1 M
C
1 I
C
Tics
1 M
S
1 I
S
1 I
S
%
1 I
S
%
1 I
S
%
2 F
S
→ Calib. units: v
2 F
S
→ Calib. units: v
2 F
S
→ Calib. units: v
2 F
S
→ Calib. units: v
No.
Type Prot. Unit
1 M
S
1 I
S
%
0x0002
Min. range for amplitude control
Max. range for amplitude control
Damping for amplitude control
Theoretical speed of sound of the fluid
FPGA AD gain 0 dB, +6 dB, -6 dB
0x0000
0x0001
0x0002
Switches signal tracking on or off
0x0000
0x0001
Max. size of the tracking window
Correlation mode
0x0000
0x0001
Length of the correlation window
Batch: Minimum amplitude
Limit for the input signal (Low)
Limit for the input signal (High)
Lower limit for the flow velocity
Upper limit for the flow velocity
Lower limit for the speed of sound
Upper limit for the speed of sound
Description
Correlation mode (3X measurement)
0x0000
0x0001
Batch: Minimum amplitude (3X meas-
urement)
Manual USM GT400 · EN10 · May 2021
HOLD
227
1 (d)
2
0.5
ON
OFF
(d)
OFF
(d)
FADE_IN
OFF
(d)
FADE_IN

Advertisement

Table of Contents
loading

Table of Contents