RMG USM GT400 Operating Manual page 238

Ultrasonic flowmeter
Hide thumbs Also See for USM GT400:
Table of Contents

Advertisement

15 Lists of parameters and measured values
Path3 Parameters
Coord. Value
AM-09 p3 f-trans set val
230
AM-10 path-3 trans. freq.
AM-11 path-3 band limits
AM-12 path-3
trans.pulses
AM-13 p3 filter selection
AM-14 path-3 tw
AM-16 path-3 DAC-G1
cmd
AM-17 path-3 DAC-G1 val
AM-18 path-3 DAC-G2
cmd
AM-19 path-3 DAC-G2 val
AM-20 p3 blanking delay
AM-21 p3 blanking count
AM-22 path-3 decay time
AM-23 path-3 path
length
AM-24 path-3 axial dist.
AM-25 p3 assembly an-
gle
AM-26 p3 delta-t offset
AM-29 const w3
AM-30 p3 tic offset
AM-31 p3 tic offset (X)
AM-32 p3 AGC-limit
AM-34 p3 no. of f-
batches
Manual USM GT400 · EN10 · May 2021
Reg.
No.
Type Prot. Unit
2504
2 L
S
Hz
2524
2 L
R
Hz
2192
1 I
S
%
2042
1 I
S
2172
1 M
S
kHz
1084
2 F
S
us
2052
1 I
S
2062
1 I
S
2072
1 I
S
2082
1 I
S
1104
2 F
R
us
2544
2 L
R
tic
1124
2 F
S
ms
1144
2 F
S
→ Calib. units:
1164
2 F
S
→ Calib. units:
1504
2 F
S
°
1424
2 F
S
us
1244
2 F
S
[1]
2202
1 I
S
tic
2262
1 I
S
tic
2222
1 I
S
dB
2314
1 I
C
Description
Path 3 transmit frequency intended
value in Hz
Path 3 transmit frequency actual value
in Hz
Path 3 limits to observe
Path 3 number of transmit pulses
Path 3 DSP filter selection
0x0000
0x0001
0x0002
0x0003
0x0004
0x0005
0x0006
0x0007
0x0008
0x0009
0x000a
0x000b
Path 3 delay time
Path 3 DAC-G1 command register
Path 3 DAC-G1 data register
Path 3 DAC-G2 command register
Path 3 DAC-G2 data register
Path 3 blanking delay
Path 3 blanking count
Path 3 pulse decay time
Length Path 3 path length
Length Path 3 smallest path distance
Path 3 assembly angle
Path 3 time difference offset
Path 3 weigthing factor w3
Path 3 tic offset
Path 3 tic offset (3X-measurement)
Path 3 AGC limit
Path 3 no. of measurement (FBatches)
50
75
100 (d)
125
150
175
200
225
250
275
300
325

Advertisement