The value specifies how many values - of a maximum possible determinable quan-
tity - could be taken into account. If one of ten measurements within a measure-
ment cycle for a path is wrong (i.e. 9 valid measurements) the DSP provides 90%
valid measurements, and the path performance is 90%.
The overall performance is the average of the performance of all individual paths
(L-6 to Q-6, valid measurement G1 - G6) for the last n measurements (n = moving
average in E-09; the default is 10 measurements).
Notice
The USM-GT-400 keeps its calibrated accuracy even if up to 2 measurement
paths fails! The value "signal acceptance" falls down to 66% then.
Exceptions:
If | Vw | <VwUg (the speed is below the minimum speed), then the path perfor-
mance and the overall performance goes to 100%.