RMG USM GT400 Operating Manual page 34

Ultrasonic flowmeter
Hide thumbs Also See for USM GT400:
Table of Contents

Advertisement

3 Device overview
The ultrasonic gas meter consists of the following main components:
Covers of the transducers (1 and 2)
The covers protect the connections and the lines of the transducer (TD) against
26
contamination and mechanical damage.
Ultrasonic electronics (3)
The ultrasonic electronics is in a pressure tight, encapsulated housing mounted on
the ultrasonic gas meter. The ultrasonic electronics evaluates the data recorded by
the transducers. In addition to the display, the parameters can be shown and eval-
uated on a computer using the RMGViewUSM software.
Lifting eyes (4)
The lifting eyes can be used to safely transport the device using a suitable lifting
gear.
Connection flange (5)
The device is bolted onto the gas line using the connection flanges.
Transducer (6)
The transducers are installed in the housing of the ultrasonic gas meter and are
not visible once installed.
Retaining bolts (7)
The retaining bolts are mounted when delivering the device. The retaining bolts
secure the product from tipping over or rolling away. The bolts must be mounted to
ensure for a safe installation or de-installation.