10 Operation
identified via its firmware version and its checksum (CRC-16). Therefore, for
matching checksum and version number is deposited at the PTB (registration au-
thority). The checksum itself can be verified via the display or via Modbus.
138
10.1.6

Adaptation of the DZU protocol to ERZ 2400

DZU protocol (DZU slave) becomes bus-capable adjusting the coordinates of the
bus address:
1. J-01 mode serial 0 (extended menu: DZU-Slave)
2. J-12 DZU-0 address
3. J-14 mode serial 1 (extended menu: DZU slave)
4. J-23 DZU-1 Address
5. J-25 opt. ser2 mode (extended menu: DZU-Slave)
6. J-37 DZU-2 address
Notice
This mode can be used only in areas where the MID is applied!
Manual USM GT400 · EN10 · May 2021