7 Construction and Planning
92
With this installation option, two or several devices are connected with one-
another via the flanges. Third-party manufacturer devices can also be connected
to RMG devices.
For this purpose, a tapered bore can be applied to the flanges on the inlet and out-
let piping.
The flanges that are used to connect the devices with one-another do not require a
tapering. For third-party manufacturer devices, you have to check if a tapering is
required.
Notice
For the device with the smaller inner diameter it is mandatory to use a tapering.
If two RMG devices are connected with one-another, the inner diameter must be
continuously the same.
Different sized devices cannot be connected to one-another.
Manual USM GT400 · EN10 · May 2021
1
Tapered bore
2
Inner diameter
Fig. 7.9: Face-to-Face Installation