The special tool from RMG must be used for changing the transducers.
You can find out more about changing the transducers with the tool here:
Service manual for changing the transducers and ultrasonic electronics (sepa-
rate document)
11.6 Changing the ultrasonic electronics
Danger
Mortal danger from incorrect replacement of the transducer
If transducers of a system under pressure are not changed correctly, this may
cause an explosion. Escaping gas may lead to intoxication.
• Change the transducer only if you have obtained a training from RMG for
this activity.
• Observe the separate service instructions for changing the transducer.
You can find out more about changing the ultrasonic electronics here:
Service manual for changing the transducers and ultrasonic electronics (sepa-
rate document)
11.7 Cleaning the device
Notice
Malfunction from soiling
If the device is soiled on the inside, it cannot function correctly. This may lead to
incorrect measuring values or a failure.
• Have a device that is contaminated on the inside only cleaned by RMG ser-
vice or by personnel that have been especially trained by RMG.
Damage to the device from incorrect cleaning agent
If the device is cleaned with cleaning agent containing solvents or other unsuita-
ble agents, the paint or plastic parts become brittle, for example.
• Use gentle cleaning agents that are suitable for glass surfaces, metal and
plastic.
11 Maintenance
Manual USM GT400 · EN10 · May 2021
167