4 Functional principle – Ultrasonic-flow measurement
Legend
36
Typical values at very good flow conditions for middle paths are at 2-3%, for the
outer paths, the turbulence increases to 4%. If these values are above 10%, then
disturbed conditions can be assumed affecting the measurement accuracy. At
lowest velocities the turbulence calculation is switched off.
Profile and symmetry factor
For a fully developed flow the middle path (3 + 4) have the highest velocity, the
two outer paths (1 + 2; 5 + 6) are more or less equal. The profile factor ( PF ) is
typically between 1.05 to 1.20; at values below 1.00 or above 1.50, the flow condi-
tions should be checked.
2 ( ̅
=
(
+ ̅
1
Profile factor
The symmetry factor ( SY ) usually is between 0.9-1.10; at values below 0.75 or
above 1.25 the flow conditions should be checked.
( ̅
+ ̅
5
=
(
+ ̅
1
Symmetry factor
Meter performance
This value ( MP ) indicates whether the velocity of all ultrasonic paths could be
measured and involved in the flow calculation. It is calculated on base of the last
20 measurements (same as turbulence).
∑
1..100
=