Inner Diameter Of Connecting Spool Pieces - RMG USM GT400 Operating Manual

Ultrasonic flowmeter
Hide thumbs Also See for USM GT400:
Table of Contents

Advertisement

Di-1 = inner diameter (tapered, schedule 80)
Di-2 = inner diameter full bore (schedule 40)
1
Maximum diameter at the flange, depending on tapering.
2
Approximate dimension.
3
Approximate values. Weights can vary due to casting tolerances.
An angle of 7° is used for tapering.

13.6 Inner diameter of connecting spool pieces

Connection diameter at tapering of the USM GT400
(= inner diameter for inlet and outlet spool pieces)
Maximum deviation from meter to piping:
+/- 1% acc. MID
For calibrated spool pieces belonging to the measuring instrument, the deviation
may be up to +/- 3%. For the full-bore version, generally +5% / -2% are allowed re-
gardless of the use during calibration.
The blue marked inner diameters for every ANSI pressure rating are to be under-
stood as a recommendation if no inner diameter is specified by the customer.
Meter
size
in DN
/ Inch
80
80
80
80
80
80
100
100
100
100
100
100
100
100
150
150
Pressure
Inner
class
Diameter
ANSI150
73,7
ANSI150
77,9
ANSI300
73,7
ANSI300
77,9
ANSI600
73,7
ANSI600
77,9
ANSI150RF
97.2
ANSI150RF
102.3
ANSI300RF
97.2
ANSI300RF
102.3
ANSI600RF
97.2
ANSI600RF
102.3
ANSI600RTJ
97.2
ANSI600RTJ
102.3
ANSI150RF
146.4
ANSI150RF
154.1
13 Technical specifications
Min. ID
Max. ID
Schedule
of spools
of spools
73
74,4
80
77,2
78,7
40
73
74,4
80
77,2
78,7
40
73
74,4
80
77,2
78,7
40
96.2
98.2
80
101.3
103.3
40
96.2
98.2
80
101.3
103.3
40
96.2
98.2
80
101.3
103.3
40
96.2
98.2
80
101.3
103.3
40
144.9
147.9
80
152.6
155.6
40
Manual USM GT400 · EN10 · May 2021
189

Advertisement

Table of Contents
loading

Table of Contents