8 Installation
▪ Establish connection at the female thread
130
Fig. 8.40: Connection options of the pressure connection with female thread
1
Unscrew the blind plug (2).
2
Seal the connection in the female thread (1).

8.5 Outdoor installation

The USM-GT-400 may be installed outdoor, too. Doing this requires some
important considerations and advices:
1. Please pay attention to the ambient temperature, it must not exceed the range
from -40°C to 55°C.
2. Please prevent any contact of the USM-GT-400 with chemically aggressive
gases and vapors. These gases and vapors may not damage the protective
coating nor the materials used. The materials used can be found below in the
section "Technical data".
3. The USM-GT-400 may not be completely buried or submerged in water.
4. The display must not be exposed to direct sunlight for a longer period of time
(> 5 minutes). In this case please use the recommended sun
protection (see next picture), that can be supplied from RMG service.
Manual USM GT400 · EN10 · May 2021