ABB CPS6000 Product Manual page 79

-48v indoor/outdoor power shelf
Hide thumbs Also See for CPS6000:
Table of Contents

Advertisement

Local RS232 Serial Port Connector
A DB-9 connector (J3) with a male housing and female pins supporting a local RS-232 port with a
subset of handshake signals is provided for local terminal access. This connector provides an isolated
RS-232 communication port for notebook computers and PCs.
The local port pin assignments should take the assignment as a Data Circuit-terminating Equipment
(DCE). This assignment is shown in the following table.
Pin
1
2
3
4
5
6
7
8
9
* These signals are not necessary for supporting a local port connection.
LAN Connection (Ethernet)
A standard integrated RJ-45 receptacle (P6) is provided on the QS841A for connecting to an
appropriate 10/100 Base-T LAN. P6 is shielded with the shield being tied to chassis. This connector is
accessible when the controller is inserted in the shelf. The signals and pin assignments for this
interface follow industry standard and are shown in the following table:
Pin
1
2
3
4
5
6
7
8
Page 79
© Copyright 2021 ABB. All rights reserved.
Signal
Description
RS-232 DCD
*RS-232 Data Carrier Detect (output)
RS-232 TXD
RS-232 Transmit (output)
RS-232 RXD
RS-232 Receive (input)
RS-232 DSR
RS-232 Data Set Ready (input)
RS-232 ISO GND
RS-232 Isolated Ground
RS-232 DTR
*RS-232 Data Terminal Ready (output)
RS-232 CTS
RS-232 Clear To Send (input)
RS-232 RTS
RS-232 Request To Send (output)
NC
No Connect
Signal
TX+
TX-
RX+
n/c
n/c
RX-
n/c
n/c
Description
Tranceive Data+
Tranceive Data-
Receive Data+
Not connected
Not connected
Receive Data-
Not connected
Not connected

Advertisement