Set Enhanced Flashcopy Group Attributes - IBM System Storage DS3000 Programming Manual

Hide thumbs Also See for System Storage DS3000:
Table of Contents

Advertisement

Parameters
Parameter
enclosure
powerFan
interconnect
battery
esm
serviceAllowedIndicator
Example
This command turns on the Service Action Allowed indicator light for the left ESM on enclosure 5 with
the IP address of 155.155.155.155.
SMcli 155.155.155.155 -c "set enclosure [5] ESM [left] serviceAllowedIndicator=on";
Notes
This command was originally defined for use with the DS4800 (Models 82, 84, 88) controller enclosure.
This command is not supported by controller enclosures that were shipped before the introduction of the
DS4800 (Models 82, 84, 88) controller enclosure.

Set Enhanced FlashCopy Group Attributes

This command defines the properties for an Enhanced FlashCopy group.
Syntax
set enhancedFlashCopyGroup ["
enhancedFlashCopyGroupName"]
[userLabel="enhancedFlashCopyGroupName" |
repositoryFullPolicy=(failBaseWrites |
purgeEnhancedFlashCopyImages) |
Description
The enclosure where the power-fan CRU, the
interconnect-battery CRU, or the ESM CRU resides.
Enclosure ID values are 0 to 99. Enclose the enclosure ID
value in square brackets ([ ]). If you do not enter a
enclosure ID value, the enclosure ID of the controller
module is the default value.
The Service Action Allowed indicator light on the
power-fan CRU that you want to turn on or turn off.
Valid power-fan CRU identifiers are left or right. The
values left and right are with respect to the front of the
DS5300–, DS5100–, and DS4800–series controller
modules. Enclose the power-fan CRU identifier in square
brackets ([ ]).
The Service Action Allowed indicator light for the
interconnect-battery CRU DS5300–, DS5100–, and
DS4800–series controller modules only.
The Service Action Allowed indicator light for a battery.
Valid battery identifiers are left or right. The values
left and right are with respect to the front of the
DS5300–, DS5100–, and DS4800–series controller
modules.
The Service Action Allowed indicator light for an ESM
CRU. Valid ESM CRU identifiers are left or right. (The
values left and right are with respect to the rear of the
drive expansion enclosure.)
The setting to turn on or turn off the Service Action
Allowed indicator light. To turn on the Service Action
Allowed indicator light, set this parameter to on. To turn
off the Service Action Allowed indicator light, set this
parameter to off.
Chapter 3. Script Commands
3-203