Set Enclosure Identification

This command sets the enclosure ID of a controller module or an expansion drawer in a storage
subsystem. This command is valid only for controller modules or expansion drawers that have enclosure
IDs that you can set through the controller firmware. You cannot use this command for controller
modules or expansion drawers that have an enclosure ID that you set with a switch.
Syntax
set enclosure ["serial-number"] id=enclosureID
Parameters
Parameter
Description
The serial number of the controller module, controller module,
enclosure
or the expansion drawer for which you are setting the
enclosure ID. Serial numbers can be any combination of
alphanumeric characters and any length. Enclose the serial
number in double quotation marks (" ").
id
The value for the controller module enclosure ID, controller
module enclosure ID, or the expansion drawer enclosure ID.
Enclosure ID values are 00 through 99. You do not need to
enclose the enclosure ID value in parentheses.
Notes
This command originally supported the DS4800 (models 82, 84, and 88) controller module. The DS4200–,
DS4700–, and DS4800– (models 82, 84, and 88) series controller modules can connect to a variety of
expansion drawers, including those whose enclosure IDs are set by switches. When connecting a
controller module to expansion drawers whose enclosure IDs are set by switches, recommended values
for enclosure IDs for the controller module are 80 through 99. This range avoids conflicts with enclosure
IDs that are used for attached expansion drawers.

Set Enclosure Service Action Allowed Indicator

This command turns on or turns off the Service Action Allowed indicator light on a power-fan CRU, an
interconnect-battery CRU, or an environmental services monitor (ESM) CRU. If the storage subsystem
does not support the Service Action Allowed indicator light feature, this command returns an error. If the
storage subsystem supports the command but is unable to turn on or turn off the indicator light, this
command returns an error.
To turn on or turn off the Service Action Allowed indicator light on the controller CRU, use the set
controller serviceAllowedIndicator command.
Syntax
set enclosure [enclosureID]
(powerFan [(left | right)] |
interconnect |
battery [(left | right)] |
esm [(left | right)])
serviceAllowedIndicator=(on | off)