Parameter
Parameter
file
Save Storage Subsystem SOC Counts
This command saves the SOC error statistics to a file. This command is valid only for Fibre Channel
devices in an Arbitrated Loop topology.
Syntax
save storageSubsystem SOCCounts file="filename"
Parameter
Parameter
file
Notes
To more effectively save SOC error statistics to a file, perform these steps:
1. Run the reset storageSubsystem SOCBaseline command to set all of the SOC counters to 0.
2. Run the storage subsystem for a predetermined amount of time (for example, two hours).
3. Run the save storageSubsystem SOCCounts file="filename" command.
Save Storage Subsystem State Capture
This command saves the state capture of a storage subsystem to a file.
Syntax
save storageSubsystem stateCapture file="filename"
Description
The file path and the file name to which you want to save
the SYSPHY counters. Enclose the file path and the file name
in double quotation marks (" "). For example:
file="C:\Program Files\CLI\logs\sasphy.csv"
This command does not automatically append a file
extension to the saved file. You can use any file name but
you must use the .csv extension.
Description
The name of the file to which you want to save the SOC error
statistics. Enclose the file name in double quotation marks
(" ").
Chapter 3. Script Commands
3-181
Need help?