Set Enclosure Alarm - IBM System Storage DS3000 Programming Manual

Hide thumbs Also See for System Storage DS3000:
Table of Contents

Advertisement

Parameter
Parameter
Description
drive
The enclosure, drawer, and the slot where the disk drive resides.
EnclosureID1,drawerID1,slotID1 ... enclosureIDn,drawerIDn,slotIDn
is for enclosures with multiple disk drive drawers. For enclosures
without disk drive drawers, use enclosureID1,slotID1 ...
enclosureIDn,slotIDn instead. Enclosure ID values are 0 to 99.
Drawer ID values are 1 to 5. Slot ID values are 1 to 32. Enclose the
values in square brackets ([ ]).
Notes
The drive parameter supports both high-capacity drive expansion enclosures and low-capacity drive
expansion enclosures. A high-capacity drive expansion enclosure has drawers that hold the drives. The
drawers slide out of the drive expansion enclosure to provide access to the drives. A low-capacity drive
expansion enclosure does not have drawers. For a high-capacity drive expansion enclosure, you must
specify the identifier (ID) of the drive expansion enclosure, the ID of the drawer, and the ID of the slot in
which a drive resides. For a low-capacity drive expansion enclosure, you need only specify the ID of the
drive expansion enclosure and the ID of the slot in which a drive resides. For a low-capacity drive
expansion enclosure, an alternative method for identifying a location for a drive is to specify the ID of
the drive expansion enclosure, set the ID of the drawer to 0, and specify the ID of the slot in which a
drive resides.

Set Enclosure Alarm

This command turns on, turns off, or mutes the audible alarm for a specific enclosure or all of the
enclosures in a storage subsystem.
Syntax
set (allenclosures | enclosure [enclosureID]
alarm=(enable | disable | mute))
Parameters
Parameter
Description
The setting to select all of the enclosures in a storage
allEnclosures
subsystem that have audible alarms that you want to turn on,
turn off, or mute.
enclosure
The specific enclosure that has the audible alarm that you
want to turn on, turn off, or mute. Enclosure ID values are 0
to 99. Enclose the enclosure ID value in square brackets ([ ]).
You can specify only one enclosure ID at a time
The setting for the audible alarm. This alarm has these values:
alarm
v enable – The audible alarm is turned on and sounds if a
v disable – The audible alarm is turned off and does not
v mute – The audible alarm is turned off if it is sounding.
(If another fault occurs after you set the audible alarm to mute,
the audible alarm sounds again.)
fault occurs.
sound if a fault occurs.