Hydraulic tank breather
Replace the hydraulic tank breather every 1000 h
1. Keep pressed the button (1) on the top of the breather
to release all the pressure in the hydraulic tank.
2. Clean the top surface of the hydraulic tank.
3. Remove the button (1) from the breather.
4. Remove the nut (2) and the cover (3).
5. Remove and discard the used filter element (4).
6. Attach a new element (4) with the seal (5) facing up.
7. Attach the cover (3) together with the nut (2).
8. Attach the button (1).
6 - MAINTENANCE
6-50
1
SMIL19CEX0597AA
2
SMIL14CEX2782BB