Case CX490D Operator's Manual page 151

Crawler excavator
Hide thumbs Also See for CX490D:
Table of Contents

Advertisement

If an EGR system abnormality is detected within 40 h after completion of EGR system repair, and the detection lasts
for 10 s, the machine control system immediately resumes the inducement sequence to the step (C).
Rear camera view operating mode.
(C) EGR problem.
SCR detection icon slow flashing.
Three short beeps.
(D) After 5 h with no action taken.
SCR detection icon fast flashing.
Continuous beep.
At the step (D), the operation of the machine shall be
stopped. Reach a safe condition for the machine, and
immediately call the CASE CONSTRUCTION dealer for
inspection and repair of the EGR system.
3 - CONTROLS AND INSTRUMENTS
displayed.
displayed.
3-99
28
SMIL17CEX0126AA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx500d

Table of Contents