6. Select the filling method using the selector switch
located on the right side of the filling pump:
○ Auto mode: the pump stops filling automatically and
the audible alarm sounds when the fuel tank is full.
○ Manual mode: monitor the filling from the fuel tank
gauge. Stop when the fuel reaches the maximum
level.
7. Turn the main switch of the pump to ON position. Fill-
ing begins.
8. When the fuel tank is full, turn the main switch of the
pump to OFF position. In Auto mode, the audible
alarm device will cease to function.
NOTE: It is possible to stop filling at any time by turning
the main switch of the pump to OFF position.
9. Run the pump for a few moments to empty the pipe
outside the drum. Clean and replace the inlet pipe in
the front storage box.
10. Refit the fuel tank filler cap.
11. Turn the starter key to OFF position.
NOTE: The pump is equipped with a 10 A fuse.
3 - CONTROLS AND INSTRUMENTS
3-77
4
SMIL14CEX2517AA
5
SMIL14CEX2518AA