Hydraulic oil level

WARNING
Burn hazard!
Before performing any service on the hydraulic system, you must allow it to cool. Hydraulic fluid
temperature should not exceed 40 °C (104 °F).
Failure to comply could result in death or serious injury.
Check the hydraulic oil level every 10 h or every day
Fluid: CASE AKCELA HYDRAULIC LL 46
1. Park the machine on a flat and level place, and arrange
the attachment as shown in the figure. Stop the engine,
and remove the starter key.
2. Open the right-hand door, and check the indicator of
the hydraulic oil level. The oil level should be in the
middle of the band indicated by the two lines.
3. If the hydraulic oil level is not in range proceed as fol-
lows:
• Release all pressure in the hydraulic tank. Refer to
page 6-10.
• Clean the top surface of the hydraulic tank.
• Remove the cover of the suction filter, and supply
hydraulic fluid to the tank.
• If necessary, replace the seal of the cover plate, and
attach the cover of the suction filter.
NOTICE: make sure that no contaminant (water, sand etc.)
enters the reservoir during filling.
6 - MAINTENANCE
6-19
W0241A
1
SMIL15CEXY218AA
2
SMIL15CEXY219AA
3
SMIL15CEXY220AA