The machine control system provides specific combinations of visual and acoustic signals in order to make the oper-
ator aware of the starting and the progressing of an inducement sequence.
Inducement sequence for refilling DEF/AdBlue®
Rear camera view operating mode.
(A) Level of DEF/AdBlue® around 10% of tank capacity.
DEF/AdBlue® gauge white.
(B) Level of DEF/AdBlue® below 10% of tank capacity.
DEF/AdBlue® gauge orange.
DEF/AdBlue® refill warning displayed.
displayed.
One long beep.
(C) Level of DEF/AdBlue® below 5% of tank capacity.
DEF/AdBlue® gauge orange and flashing.
DEF/AdBlue® refill warning slow flashing.
displayed.
Three short beeps.
(D) DEF/AdBlue® tank empty
DEF/AdBlue® gauge red.
DEF/AdBlue® refill warning fast flashing.
displayed.
Continuous beep.
At the step (D), the operation of the machine shall be
stopped. Reach a safe condition for the machine, and
immediately refill DEF/AdBlue® into the tank according
to the procedure described in the next page.