3 - CONTROLS AND INSTRUMENTS
Explanation
CHECK CAMERA: The cameras or
the camera wirings have a failure.
LOW COOLANT: The level of the
coolant in the engine cooling system
is low.
AIR FILTER: The air cleaner element
is clogged.
HYD. OIL FILTER: The hydraulic
return filter is clogged.
The message is active if the machine
is equipped with Single-acting or
Multi-function auxiliary high-flow
hydraulic circuit.
FUEL FILTER: The fuel pre-filter or
the fuel main filter is clogged. The
engine goes automatically to low idle.
CHECK SCR SYSTEM: The SCR
system has a failure and does not
function properly.
Explanation
ENGINE STOP: the engine has
been stopped by the emergency stop
switch.
IMPROPER SHUT DOWN: The
engine has been stopped without
cooling it down.
OVER LOAD: an overload condition
is detected during the handling of an
object.
LOW FUEL: The fuel level in the tank
is low.
CHECK FLOW RATE: The set up of
the auxiliary hydraulics is not proper.
AUXILIARY SET-UP REQUIRED:
The operation with the hydraulic
attachment is attempted without any
set up of the auxiliary hydraulics.
SERVICE DUE: One or more
periodical maintenance operations
are due.
IDLE SHUT DOWN: The engine is
going to stop automatically within
10 s.
REFILL DEF: The level of
DEF/AdBlue® in the tank is
low.
3-44
Action
Stop the engine, and contact the
CASE CONSTRUCTION dealer
immediately.
Stop the engine, and refill the
reserve tank with coolant. Start
the engine, and check for coolant
leaks. If any leak is found, or if
the message persists, contact the
CASE CONSTRUCTION dealer
immediately.
Stop the engine, and clean or replace
the air cleaner element.
Stop the engine and check the
hydraulic return filter. Replace it if
any clogging is found.
Stop the engine, and replace the
filter element. Start the engine, and
if the message persists, contact
the CASE CONSTRUCTION dealer
immediately.
Stop the engine, and contact the
CASE CONSTRUCTION dealer
immediately.
Action
To start the engine again, press
on the back of the emergency stop
switch, turn the starter key to OFF
position, and then restart the engine.
Restart the engine, and keep it at a
low idle for at least 5 min.
Place the load onto the ground and
check the load conditions making
reference to the chart located inside
the cab.
Stop the engine, and add fuel to the
fuel tank.
Check the specifications of the
attachment currently in use, and set
appropriate flow.
Check the specifications of the
attachment currently in use, and
set up the auxiliary hydraulics
accordingly.
Check the maintenance chart, and
carry out the required maintenance
operations.
If needed, set the gate lock lever
in forward position to restart normal
operation.
Stop the engine, and add
DEF/AdBlue® to the DEF/AdBlue®
tank.