Mitsubishi Electric MELSEC-LD77MS2 User Manual page 1020

Hide thumbs Also See for MELSEC-LD77MS2:
Table of Contents

Advertisement

(2) OPR
The method and some operation of the OPR using AlphaStep/5-phase
differ from those of the OPR using the servo amplifier.
(a) OPR method that can be used
Pr.43
Near-point dog method
Count method 1)
Count method 2)
Data set method
Scale origin signal detection method
Driver OPR method
1: The error "OPR method invalid" (error code: 232) occurs and OPR is not
performed.
(b) Driver OPR method
The following shows an operation outline of the OPR method "Driver
OPR method".
The OPR is executed based on the positioning pattern set in
AlphaStep/5-phase. Set the setting values of OPR in the parameters of
AlphaStep/5-phase. The operation of OPR and "b0: Lower limit", "b1:
Upper limit" and "b6: Near-point dog signal" of "
" depend on the specification of AlphaStep/5-phase, so that
selection
refer to the AlphaStep/5-phase manual and match the settings. For
parameters that can be set by the Simple Motion module, refer to
Section 5.1.3 "Setting items for OPR parameters".
This method is not available except for the stepping driver. If the
method is executed, the error "OPR method invalid" (error code: 232)
occurs.
(c) Backlash compensation after the driver OPR method
When "
Backlash compensation amount
Pr.11
module, whether the backlash compensation is necessary or not is
judged from "
axis operation such as positioning after the driver OPR. When the
positioning is executed in the same direction as "
the backlash compensation is not executed. However, when the
positioning is executed in the reverse direction against "
", the backlash compensation is executed.
direction
Note that the OPR is executed based on the OPR direction of the
parameter of AlphaStep/5-phase during the driver OPR. Therefore, set
the same direction to "
and the OPR direction of the parameter of AlphaStep/5-phase.
Appendix - 72
OPR method
: Possible
: Not possible
" of the Simple Motion module in the
OPR direction
Pr.44
OPR direction
Pr.44
Appendices
Possible/Not possible
* 1
* 1
* 1
Input signal logic
Pr.22
" is set in the Simple Motion
OPR direction
Pr.44
OPR
Pr.44
" of the Simple Motion module
",

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l seriesMelsec-ld77ms4Melsec-ld77ms16

Table of Contents