Classification
Error code
of errors
61712 (F110H)
61713 (F111H)
61714 (F112H)
61715 (F113H)
61716 (F114H)
61717 (F115H)
61718 (F116H)
61719 (F117H)
61720 (F118H)
61721 (F119H)
Inverter
61728 (F120H)
FR-A700
61729 (F121H)
series
61730 (F122H)
61731 (F123H)
61732 (F124H)
61735 (F127H)
61736 (F128H)
61737 (F129H)
61744 (F130H)
61745 (F131H)
61746 (F132H)
61747 (F133H)
61748 (F134H)
61749 (F135H)
61750 (F136H)
[4] FR-A700 series detection error/warning
(1) Error
When an error occurs on FR-A700 series, the error code (61696 to 61951) is
stored in "
Md.23
"
Servo alarm
Md.114
always stored in "
(b14)" of "
Md.108
The detection error list for FR-A700 series is shown below.
Confirm the instruction manual of FR-A700 series for details.
Alarm No. of
FR-A700 series
10H
11H
12H
13H
14H
15H
16H
17H
18H
19H
20H
21H
22H
23H
24H
27H
28H
29H
30H
31H
32H
33H
34H
35H
36H
". The alarm No. of FR-A700 series is stored in
Axis error No.
" and "
Servo alarm
Md.57
Parameter error No.
Md.107
".
Servo status
FR-A700 series
LED display
E.OC1
Overcurrent trip during acceleration
E.OC2
Overcurrent trip during constant speed
E.OC3
Overcurrent trip during deceleration or
stop
E.OV1
Regenerative overvoltage trip during
acceleration
E.OV2
Regenerative overvoltage trip during
constant speed
E.OV3
Regenerative overvoltage trip during
deceleration or stop
E.THM
Motor overload trip (electronic thermal
relay function)
E.THT
Inverter overload trip (electronic
thermal relay function)
E.IPF
Instantaneous power failure
E.UVT
Undervoltage
E.BE
Brake transistor alarm detection
E.GF
Output side earth (ground) fault
overcurrent
E.OHT
External thermal relay operation
E.OLT
Stall prevention stop
E.OPT
Option fault
E.PE
Parameter storage device fault
E.PUE
PU disconnection
E.RET
Retry count excess
E.CPU
CPU fault
E.ILF
Input phase loss
E.FIN
Heatsink overheat
E.OS
Overspeed occurrence
E.OSD
Speed deviation excess detection
E.ECT
Signal loss detection
E.OD
Excessive position fault
Appendix - 65
" in error history. However, "0" is
" and "Absolute position lost
Name
Not be output
when using
FR-A7NS.
Appendices
Remarks