78 General Maintenance
8.
Lock out and tag out the vehicle (see Locking Out and Tagging Out the Vehicle on page 14).
NEXT: REMOVING PACKER PANEL: See "C. Removing Packer Panel - Co-Mingle Units W/
Loading Arm" on page 84.
D. Disconnecting Packer - Co-Mingle Units W/O Loading Arm
Once you have gained access to the packer, you must now disconnect it. To do so:
1.
Remove the access cover on the packer panel to reach the cylinder pin.
Take out the 2 bolts that hold the access cover in (see Figure 3-82).
Figure 3-82
Access cover
2.
Disconnect the cylinder pin from the greasing hoses (see Figure 3-83).
Figure 3-83
Cylinder pin
3.
Remove the cylinder pin.
Take 2 5/8-18 NF, 9-inch long fine-threaded bolts and screw them in the pin head holes.
Loosen these 2 bolts to
Cylinder pin
hoses from cylinder pin
Remove
these 2 bolts