6.
Remove the strainer from the tank port along with the shut-off valve (ball valve) [see Figure
5-24].
7.
Unscrew the strainer.
The strainer has to be turned counter-clockwise to be removed.
8.
Clean the strainer using solvent, and check for damage; replace if necessary.
9.
Apply thread seal compound on the strainer threads and reinstall the strainer.
10.
Replace the seal, if necessary [see Figure 5-24].
Figure 5-23
Suction line
Shut-off
valve
Figure 5-24
Strainer
Strainer
Suction
hose
Clamps
Hydraulic System 281
Seal
Flange