Next, place the red lead on pin 1 and the black lead on pin 2. There should not be continuity through
the diode.
If the diode passed the above test proceed to step #6.
If the diode did not pass the above test replace the diode and then proceed to step #6.
N
: Connector CM28 & wire 149 on the illustrations are for reference only; the specific connector
OTE
& wire numbers may vary. To find the diode on the wiring schematic, locate wire #130 and
trace it to the diode pack, typically on page 1.
Step #6) Reconnect the diode onto wires 130 and 149. Check for voltage on wire 149.
If voltage is not present, then the diode continuity check was performed incorrectly. Replace the
diode.
If voltage is present on wire 149 then proceed to step #7.
Step #7) Locate wire 149 at Node 10, connector X10, pin 16 AND spade location 1 of the pump
relay. Check for voltage.
If voltage is present, then the node 10 is defective/damaged, replace it.
If no voltage is present, then the 149 wire is broken between the diode location and Node 10.
Locate the break and repair.