12.
Connect the pump to the PTO extension shaft. Align the splines on the PTO to those on the
pump for ease of connection.
Figure 5-13
Splines on pump
13.
Put all 5/8" bolts back in to secure the pump to the shaft.
14.
Go through Steps 8 to 5 inclusively to reinstall the various components of the pump assembly.
15.
Retighten the breather cap.
16.
Prime the new pump (see Priming New Pump on page 275).
Caution!
Check level of hydraulic oil in tank. Add oil if needed.
N
: Labrie Enviroquip Group strongly recommends you change the filter element and the
OTE
hydraulic oil as well as clean the hydraulic tank after installation of a new pump (see Replacing
Filter Elements on page 282 and Replacing Hydraulic Oil on page 283).