368 Multiplexing
This page contains a set of rectangles. Each of these rectangles is numbered and relates to a specific
function of the truck.
Colors are used to indicate whether the corresponding function is active or not:
 a blue rectangle means the corresponding function is inactive
 a green rectangle means the corresponding function is active
Also:
 a red rectangle means there is a closed short-circuit
 a yellow rectangle means there is an open circuit
A white-bordered rectangle means that this rectangle is selected. Use the directional arrows to select a
specific rectangle or function. When a rectangle is selected, a short description of the corresponding
function appears in the lower part of the screen.
After selecting a rectangle:
 press "ON" to activate the corresponding function (rectangle turns from blue to green)
 press "OFF" to deactivate the corresponding function (rectangle turns from green to blue)
 press "RESET" to have the software control the status of the corresponding function
N
: To cancel changes made in this page and restore the default values, simply cut power to the
OTE
multiplexed system by turning the ignition key off.
N
: To go from a module to another (e.g. from module 10 to 50), the operator has to go back to the
OTE
Module I/O Status page (see Figure 9-8) and select module 50.
Press "Esc" to return to the preceding page.
Joystick
The joystick page is accessible from the Module I/O Status page (see Figure 9-8). From that page
select "Joystick" using the up/down arrows and press "OK". The Joystick page opens (see Figure
9-15).
Figure 9-15
Joystick page