Operating Hours Counter/Service Display - WAGNER AquaCoat 5010 GA 5000EAW Operating Manual

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 03/2018

7.4.12 OPERATING HOURS COUNTER/SERVICE DISPLAY

Two hour counters are integrated into the control unit.
– The absolute counter measures the ongoing hours of
operation of the spray gun.
– The maintenance intervals for the spray gun can be
determined and monitored with the maintenance hours
counter.
Push button "Service"
Press the "Service" button (25) to go from the standby
position of the control unit to the service menu display.
Structure of the service menu (LED display 26 illuminates):
Push button
Description of display
R1
Display of the spray gun's absolute accrued operating hours.
Display format:
Counter reading < 999 hours: 001 = 1 hour; 291 = 291 hours.
Counter reading > 1000 hours: 1.23 = 1230 h; 45.2 = 45200 h
Maximum display value = 99.9 = 99900 h
Flashing lines are then displayed.
R2
Display of temporary maintenance counter and resetting this counter
(see Chapter 7.4.12.1).
R3
Set maintenance interval in hours, activate or lock this function
(see Chapter 7.4.12.1).
7.4.12.1 MAINTENANCE DISPLAY SETUP
When the device is first used, the function for the service interval is deactivated. This function
can be activated with the "R3" push button (19). The maintenance interval limit can be set
within a range of 0 to 999 hours.
Setting and saving the maintenance interval limit in hours
26
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
20
19
5
ORDER NUMBER DOC 2369735
Procedure
27
1. Press the "Service" button (25) to
access the service menu. LED (26)
lights up.
2. Actuate the push button R3 (19) for
a short time, the LED (20) display
lights up.
3. Use the dial (2) to set the maintenance
POWER
POWER
interval limit you want (e.g., 90 hours).
0
1
4. Check setting in the LED display (27).
5. The value is saved by pressing down
AquaCoat
the "Spray current" push button (5)
until the LED display (27) starts to
B_03383
2
flash.
26
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
POWER
POWER
0
1
AquaCoat
B_03382
68