Cleaning The Unit; Work Or Repairs At The Electrical Equipment; Maintenance Work And Breaks; Setup On An Uneven Surface - WAGNER SUPER FINISH 21 PRO Operating Manual

Airless high-pressure spraying unit
Hide thumbs Also See for SUPER FINISH 21 PRO:
Table of Contents

Advertisement

Available languages

Available languages

EN
SAFETY REGULATIONS/ GENERAL VIEW OF APPLICATION/ DESCRIPTION OF UNIT
2.17

CLEANING THE UNIT

When cleaning the gun, only rinse when the nozzle is removed
and rinse at low pressure.
When cleaning the unit with solvents, the
solvent should never be sprayed or pumped
back into a container with a small opening
(bunghole). An explosive gas/air mixture can
arise. Only use an earthed container made
from metal. To earth the gun, hold it firmly on
the edge of the container.
Danger of short-circuits caused by water in-
gression!
Never spray down the unit with high-pressure
or high-pressure steam cleaners.
2.18
WORK OR REPAIRS AT THE ELECTRICAL
EQUIPMENT
These may only be carried out by a skilled electrician. No li-
ability is assumed for incorrect installation. Unplug the power
plug from the outlet before carrying out any repair work.
2.19

MAINTENANCE WORK AND BREAKS

Before carrying out any work on the device and during any
work break, release the pressure in the spray gun and high-
pressure hose. Secure the spray gun's trigger guard and switch
off the device.
2.20

SETUP ON AN UNEVEN SURFACE

If possible do not use the unit on an inclined surface since the
unit tends to wander through the resulting vibrations.
2.21

OSCILLATION LEVEL

The specified oscillation level has been measured according
to a standard test procedure and can be used to compare
against electric tools. The oscillation level is also for determin-
ing an initial assessment of the vibrational strain.
Attention! The vibration emission value can differ from the
specified value when the electric tool is actually in use, de-
pending on how the electric tool is being used. It is necessary
to specify safety measures to protect the operating personnel.
These measures are based on an estimated shutdown during
the actual conditions of use (all parts of the operating cycle
are taken into consideration here, for example periods when
the electric tool is switched off, and, when it is switched on but
running without any load).