Maintenance Display Setup - WAGNER AquaCoat AirCoat GM 5000EACW Operating Manual

Aquacoat aircoat-spray system for noncombustible spray media aquacoat aircoat - evomotion 20-30s - wildcat 18-40 - puma 28-40 - cobra 40-10
Table of Contents

Advertisement

EDITION 04/2012
OPERATING MANUAL
5.4.17

MAINTENANCE DISPLAY SETUP

When the device is fi rst used, the function for the maintenance interval is deactivated.
This function can be activated via the the R3 push button (19). The service interval limit can
be set within a range of 0 to 999 hours.
Set and save the service interval limit in hours:
26
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
μA
R3
20
19
5
Review counter status since last service carried out on gun:
22
26
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
μA
R3
18
17
6
5
PART NO. DOC2321362
27
Works procedure:
1. Actuate the push button R3 (19) for a
short time, the LED (20) display lights
up.
2. Use the dial (2) to set the maintenance
POWER
POWER
0
1
interval limit you want (e.g. 90 hours).
3. Check setting in the LED display (27).
4. The value is saved by pressing down
AquaCoat
the „Spray current" pushbutton (5)
B_03383
until the LED display (27) starts to fl ash.
2
27
Works procedure:
1. Actuate the push button R2 (17) for a
short time, the LED (18) display lights
up.
2. Read off display in the LED display (27).
POWER
POWER
0
1
In the example 46 hours have passed
since the last spray gun service. The bar
display on the left (22) indicates that
AquaCoat
50% of the set interval time has passed.
B_03384
3. By keeping pushbutton (5) pressed
2
down, the display in the LED display
(27) can be set to „0" (reset after expiry
of the set interval limit).
AquaCoat GM 5000EACW
58

Advertisement

Table of Contents
loading

Table of Contents