SETTING THE CURRENT LIMITING

29
P_01122
2
Above the "current limiting" button 29 is the "current limiting" bar graph display 2. When
the control unit is in the ready position, this display shows the set point as a dot and when
high-voltage is switched on it shows the actual value as a bar.
The current limiting is an adjustable threshold. If this threshold is exceeded, the
high-voltage is adjusted downwards until the threshold is no longer exceeded.
ORDER NUMBER DOC 2305835
EP G
SPR INT
30
EP G
SPR INT
Prima
Procedure:
1. Press the "current limiting" button 29
to adjust the limitation of the spray
current. The yellow LED 30 indicates
that current limiting is selected.
19
2. The current limiting can now be
adjusted using the Universal rotary
controller 24 between 5 µA - 120 µA
with a resolution of 1 µA. The value is
shown in the LED display 19.
24
Sprint.