7.4.10 SETTING THE CURRENT LIMITATION

80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
6
5
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
22
Above the "Current limitation" button (5) is the "Current limitation" bar graph display (22).
If the control unit is in the ready position, this light strip shows the set value as a dot.
The current limitation is an adjustable threshold. If this threshold is exceeded, for example,
by the spray gun having approached the object being sprayed, the high voltage is adjusted
downwards until the threshold is no longer exceeded.
The set values for the target high voltage (40 kV) and for spray current limitation (83 µA)
that are shown in the examples are saved in R2 by pressing and holding (for > 2 seconds)
the receipt push button.
ORDER NUMBER DOC 2366717
Procedure
1. Press the "Current limitation"
button (5) to adjust the limitation of
the spray current.
The LED (6) indicates that current
POWER
POWER
limitation is selected.
0
1
AquaCoat
B_03377
27
2. The current limitation can now be
adjusted using the universal rotary
controller (2) between 10-100 µA
with a resolution of 1 µA.
The corresponding value is indicated
POWER
POWER
in the LED display (27).
0
1
AquaCoat
B_03378
2