Pepperl+Fuchs HD2-DM-A Manual page 29

Advanced diagnostics
Hide thumbs Also See for HD2-DM-A:
Table of Contents

Advertisement

Advanced Diagnostics
Product Description
Electromagnetic compatibility
Degree of protection
Fieldbus standard
Climatic conditions
Shock resistance
Vibration resistance
Ethernet
Ambient conditions
Ambient temperature
Storage temperature
Relative humidity
Shock resistance
Vibration resistance
Pollution Degree
Corrosion resistance
Mechanical specifications
Housing material
Housing width
Housing height
Housing depth
Degree of protection
Mass
Mounting
Data for application in connection with Ex-areas
Statement of conformity
Group, category, type of protection, tempera-
ture class
Directive conformity
Directive 94/9/EC
International approvals
IECEx approval
Approved for
General information
Supplementary information
NE 21
IEC 60529
IEC 61158-2
DIN IEC 721
EN 60068-2-27
EN 60068-2-6
IEEE 802.3
-40 ... 60 °C (-40 ... 140 °F)
-40 ... 85 °C (-40 ... 185 °F)
< 95 % non-condensing
15 g 11 ms
1 g , 10 ... 150 Hz
max. 2, according to IEC 60664
acc. to ISA-S71.04-1985, severity level G3
Polycarbonate
see dimensions
see dimensions
see dimensions
IP20
470 g
DIN rail mounting
TÜV 14 ATEX 115980 X
II 3 G Ex nA IIC T4 Gc
EN 60079-0:2012 , EN 60079-11:2012 , EN
60079-15:2010
IECEx TUN 14.0003X
Ex nA IIC T4 Gc
Statement of Conformity, Declaration of Con-
formity, Attestation of Conformity and instruc-
tions have to be observed where applicable.
For information see www.pepperl-fuchs.com.
29