Advanced Diagnostics
Appendix
Parameter
CYCLE_SEL
MIN_CY-
CLE_T
MEMORY_-
SIZE
NV_CY-
CLE_T
FREE_SPAC
E
FREE_TIME
SHED_RCAS W, S
SHED_ROUT W, S
FAULT_STAT
E
SET_FSTATE W, S
CLR_FSTATE W, S
MAX_NO-
TIFY
LIM_NOTIFY W, S
CONFIRM_-
TIME
WRITE_LOC
K
UPDATE_EV
T
BLOCK_ALM
ALARM_SUM
ACK_OP-
TION
WRITE_PRI
WRITE_ALM
ITK_VER
SERIAL_-
NUM
SW_REV
FD_VER
Char.
Description
W, S
The parameter is used to display the block implementation
method.
This parameter sets the shortest macro-cycle that can be used
by this device.
FF standard parameter. Not used.
FF standard parameter. Not used.
FF standard parameter. Not used.
FF standard parameter. Not used.
The parameter defines the time until a communication failure is
recognized in the "RCas" mode.
The parameter defines the time until a communication failure is
recognized in the "ROUT" mode.
The parameter indicates whether the device global safety sta-
tus was set. See SET_FSTATE and CLR_FSTATE.
The parameter is used to set the device global safety status.
The parameter is used to reset the device global safety status.
The parameter defines the maximum number of unacknowl-
edged alarm messages that can be managed by the device.
The parameter defines the maximum number of unacknowl-
edged alarm messages that are admitted.
W, S
The parameter sets the time during which an alarm is repeated
unless acknowledged.
The parameter indicates the position of the read-only switch.
This parameter is used to signal to the DSCS that a parameter
identified with "S" was overwritten provided that the PCS sup-
ports alarm messages.
This parameter is used to signal to the PCS diagnostic mes-
sages displayed in BLOCK_ERR provided that the PCS sup-
ports alarm messages.
The current status of the alarm messages of the block.
W, S
The parameter determines whether the alarms of the resource
block must be acknowledged.
The parameter determines the priority of the alarm messages
that are released when setting and resetting the read-only
switch.
The parameter determines if an alarm message is released
when setting and resetting the read-only switch.
The parameter assigns a version number to the interoperability
test that was used to test the device.
The parameter assigns a serial number to the device.
The parameter sets a version status of software used by the
device.
A parameter equal to the value of the major version of the field
diagnostics specification according to which this device was
designed.
167

Advertisement