  • Page 1 PROCESS AUTOMATION MANUAL Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules...
  • Page 2 Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules With regard to the supply of products, the current issue of the following document is ap- plicable: The General Terms of Delivery for Products and Services of the Electrical Indus- try, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"...
  • Page 3: Table Of Contents

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Introduction................. 4 Contents....................4 Target Group, Personnel..............4 Symbols Used ..................4 Product Specifications............... 6 Overview and Application ..............6 System Components ................7 2.2.1 Motherboard ..................7 2.2.2 Gateway Modules HD2-GTR-4PA* ............. 7 2.2.3 Power Supply Modules HCD2-FBPS-*..........
  • Page 4: Introduction

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Introduction Introduction Contents This document contains information that you need in order to use your product throughout the applicable stages of the product life cycle. These can include the following: Product identification ■...
  • Page 5 Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Introduction Warning Messages You will find warning messages, whenever dangers may arise from your actions. It is mandatory that you observe these warning messages for your personal safety and in order to avoid property damage.
  • Page 6: Product Specifications

    Class I, Division 2, gas groups A, B, C, and D. Dedicated power supply modules limit the output voltage safely according to IEC 60079–11. In combination with Pepperl+Fuchs Segment Protectors, the outputs are specified Ex ic. Thus, live maintenance at the field device level is permitted.
  • Page 7: System Components

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Product Specifications Features User benefit Lowest power dissipation of less than 2 W per Long useful lifetime. High packing density and segment under full load condition. reduced cooling requirements. Full balance of electric circuitry with high High resistance to external disturbance such isolation against radio frequency and in-band as EMI.
  • Page 8: Power Supply Modules Hcd2-Fbps

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Product Specifications 2.2.3 Power Supply Modules HCD2-FBPS-* Danger! Explosion hazard from invalidation of type of protection When using Power Hubs with suitable Segment Protectors in order to generate an intrinsically safe field wiring, exceeding the limits of the output values can overload connected field devices.
  • Page 9 Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Product Specifications The Diagnostic Manager – Professional Edition offers extra functionality: the commissioning wizard generates automated reports; the software displays clear text messages for troubleshooting of out-of-specification behavior. The OPC server transmits user-selectable common alarms to the process control system.
  • Page 10: Component Identity And Dimensions

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Product Specifications Component Identity and Dimensions MBHC-FB-4.GT* 150 mm (5.9") 135 mm (5.3") 180 mm (7.1") Motherboard MBHC-FB-4.GT Gateway module Diagnostic module Power supply modules (x 4) Trunk connection Shielding/grounding kit for trunk shields, optional accessory Connections for alarm volt-free contact and diagnostic bus (x 2) Connections for bulk power supply (x 2) Rotary switches for gateway addressing x1, x10, x100...
  • Page 11 Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Product Specifications Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 Standard conformity Electromagnetic compatibility NE 21:2011 Degree of protection IEC 60529 Fieldbus standard IEC 61158-2 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Motherboard Type MBHC-FB-4.GT Supply...
  • Page 12 Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Product Specifications Isolated Power Supply Module Type HCD2-FBPS-1.500 Supply Rated voltage 19.2 ... 35 V DC Power dissipation typ. 1.6 W Fieldbus interface Rated voltage 28 ... 29.5 V Rated current 500 ...
  • Page 13 Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Product Specifications Advanced Diagnostic Module Type HD2-DM-A Supply Rated voltage 19.2 ... 35 V Rated current 110 ... 30 mA Power loss max. 2 W Fieldbus interface Number of segments Rated voltage 9 ...
  • Page 14: Installation And Commissioning

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Installation and Commissioning Installation and Commissioning Mounting and Dismounting Danger! Danger to life from wrong mounting and installation Incorrect mounting and installation of the device can compromise its function and its electrical safety.
  • Page 15 Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Installation and Commissioning The new module has been installed. Dismounting Modules from the Motherboard To dismount a module from the motherboard, proceed as follows: Pull up the red Quick Lok Bars on each side of the module and carefully lift off the entire module.
  • Page 16: Mounting The Grounding Rail (Acc-Mb-Hsk)

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Installation and Commissioning Mounting the Grounding Rail (ACC-MB-HSK) Easy Shield Connection If required, you can attach a grounding rail to the motherboard in order to connect the shield at the trunk cable more easily. The grounding rail is available as accessory ACC-MB-HSK. Mounting the Grounding Rail (ACC-MB-HSK) Connection screws DIN 7985 M4 x 10 (2x): Use to fix the grounding rail to the mother- board...
  • Page 17: Connection To Equipotential Bonding System

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Installation and Commissioning 3.3.1 Connection to Equipotential Bonding System Caution! Risk of electric shock or property damage from inadequate grounding If you fail to connect all metal parts of the device to protective local earth correctly, this could result in potential equalization currents.
  • Page 18: Connection Layout

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Installation and Commissioning Connection Layout Danger! Explosion hazard from connection damage Manipulating connections outside of the specified ambient temperature range can lead to material damage, resulting in an unwanted failure of the connection. This could result in an increased explosion hazard in potentially explosive atmospheres.
  • Page 19 Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Installation and Commissioning Connecting the Trunk The motherboard is connected to the trunk line via designated screw or spring terminals. Trunk Connection with Screw Terminal − Segment + Segment - Shield connection Trunk Connection with Spring Terminal + - S Segment +...
  • Page 20 Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Installation and Commissioning Diagnostic Bus Connection with Spring Terminal − − Alarm RS-485 Each motherboard has 2 identical diagnostic bus terminals facing each other with inverted connections. Alarm Alarm signal lines Diagnostic bus + Diagnostic bus - Connecting the Power Supply...
  • Page 21: Connections

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Installation and Commissioning 3.4.1 Connections Primary bulk power connection Gateway host Secondary bulk power connection Common alarm volt-free contact with final motherboard link. Loop the alarm contact at the last motherboard. Diagnostic bus connection Connections for fieldbus trunk Diagnostic link cable ACC-MB-HDC...
  • Page 22: Thermal Dissipation

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Thermal Dissipation Thermal Dissipation Each power supply dissipates, i.e., loses energy in form of heat. The graphs below illustrate typical power dissipation values in watt (W) for one segment for given output currents and supply voltages.
  • Page 23 Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Thermal Dissipation Thermal Dissipation of HCD2-FBPS-1.23.500, Including Motherboard HCD2-FBPS-1.23.500 Power Dissipation in SIMPLEX Configuration per Segment 35 V 19.2 V 24 V Segment current in [mA] HCD2-FBPS-1.23.500 Power Dissipation in REDUNDANT Configuration per Segment 35 V 24 V 19.2 V...
  • Page 24: Appendix

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Appendix Appendix Ordering Information For details on all available system components and accessories, go to www.pepperl-fuchs.com and look up the corresponding online information for this product. Electromagnetic Compatibility Verification Verification in Accordance with EC Council Legislation Directive 2004/108/EC and 2014/30/EU Compatibility in Accordance with EN 61326-1 and NAMUR NE 21 Recommendation...
  • Page 25: Referenced Documents

    Fieldbus Power Hub,Motherboard for Gateway and Power Supply Modules Appendix Referenced Documents Manual: "Using Pepperl+Fuchs fieldbus equipment in Zone 2 hazardous area ■ environment" Selection table: Conformity of FieldConnex Power Hub modules and motherboards to ® ■ Ex ic...
  • Page 26 PROCESS AUTOMATION – PROTECTING YOUR PROCESS Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim · Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com For the Pepperl+Fuchs representative closest to you check www.pepperl-fuchs.com/contact www.pepperl-fuchs.com Subject to modifications / DOCT-5034 Copyright PEPPERL+FUCHS • Printed in Germany 06/2016...

This manual is also suitable for:

Hcd2-fbps-1.500Hcd2-fbps-1.23.500

Table of Contents