Advanced Diagnostics
Product Description
Indicators/operating means
LED PRI PWR
LED SEC PWR
LED Seg 1...4
Fault signal
DIP-switch
Interface
Interface type
Directive conformity
Electromagnetic compatibility
Directive 2004/108/EC
Standard conformity
Electromagnetic compatibility
Degree of protection
Shock resistance
Vibration resistance
Ambient conditions
Ambient temperature
Storage temperature
Relative humidity
Shock resistance
Vibration resistance
Mechanical specifications
Connection type
Core cross-section
Housing material
Housing width
Housing height
Housing depth
Degree of protection
Mass
Mounting
International approvals
FM approval
Approved for
3.2.3
Mounting the Stand-Alone Kit and the Advanced Diagnostic Module
For mounting the HD2-DM-A diagnostic module, see chapter 3.1.4.
green: on, primary bulk power supply con-
nected
green: on, secondary bulk power supply con-
nected
yellow: bus activity; red 2 Hz flashing: alarm;
red: hardware error
VFC alarm 1 A, 50 V DC, normally closed
diagnostic address 1...247, binary coded
diagnostic bus: RS 485
EN 61326-1:2006
NE 21
IEC 60529
EN 60068-2-27
EN 60068-2-6
-40 ... 60 °C (-40 ... 140 °F)
-40 ... 85 °C (-40 ... 185 °F)
< 95 % non-condensing
15 g 11 ms
1 g , 10 ... 150 Hz
screw terminals
2
2.5 mm
Polycarbonate
50 mm
220 mm
162 mm
IP20
approx. 290 g
DIN mounting rail
CoC 3024816, CoC 3024816C
Class I, Division 2, Groups A, B, C, D, T4 /
Class I, Zone 2, AEx/Ex nA IIC T4