HP VXI 75000 C Series User's And Scpi Programming Manual page 300

Algorithmic closed loop controller
Table of Contents

Advertisement

Command Quick Reference
Command
[SENSe:]
CHANnel
:SETTling <settle_time>,(@<ch_list>)
:SETTling? (@<channel>)
DATA
:CVTable? (@<ch_list>)
:RESet
:FIFO
[:ALL]?
:COUNt?
:HALF?
:HALF?
:MODE BLOCK | OVERwrite
:MODE?
:PART? <n_readings>
:RESet
FREQuency
:APERture <gate_time>,(@<ch_list>)
:APERture? (@<channel>)
FUNCtion
:CONDition (@<ch_list>)
:CUSTom [<range>,](@<ch_list>)
:REFerence [<range>,](@<ch_list>)
:TC <type>,[<range>,](@<ch_list>)
:FREQuency (@<ch_list>)
:RESistance <excite_current>,[<range>,](@<ch_list>)
:STRain
:FBENding [<range>,](@<ch_list>)
:FBPoisson [<range>,](@<ch_list>)
:FPOisson [<range>,](@<ch_list>)
:HBENding [<range>,](@<ch_list>)
:HPOisson [<range>,](@<ch_list>)
[:QUARter] [<range>,](@<ch_list>)
RTD, 85 | 92
TCouple, CUST | E | EEXT | J | K | N | S | T
THERmistor, 2250 | 5000 | 10000
:TEMPerature <sensor_type>,<sub_type>,
:TOTalize (@<ch_list>)
:VOLTage[:DC] [<range>,](@<ch_list>)
300 HP E1415 Command Reference
SCPI Command Quick Reference
Sets the channel settling time for channels in ch_list
Returns the channel settling time for channel
Returns elements of Current Value Table specified by ch_list
Resets all entries in the Current Value Table to IEEE "Not-a-number"
Fetch all readings until instrument returns to trigger idle state
Returns the number of measurements in the FIFO buffer
Returns 1 if at least 32,768 readings are in FIFO, else returns 0
Fetch 32,768 readings (half the FIFO) when available
Set FIFO mode.
Return the currently set FIFO mode
Fetch n_readings from FIFO reading buffer when available
Reset the FIFO counter to 0
Sets the gate time for frequency counting
Returns the gate time set for frequency counting
Equate a function and range with groups of channels
Sets function to sense digital state
Links channels to custom EU conversion table loaded by DIAG:CUST:LIN
or DIAG:CUST:PIEC commands
Links channels to custom reference temperature EU conversion table loaded
by DIAG:CUST:PIEC commands
Links channels to custom temperature EU conversion table loaded by
DIAG:CUST:PIEC, and performs ref temp compensation for <type>
Configure channels to measure frequency
Configure channels to sense resistance measurements
Links measurement channels as having read bridge voltage from:
Configure channels for temperature measurement types above:
[<range>,](@<ch_list>)
excitation current comes from Current Output SCP.
Configure channels to count digital state transitions
Configure channels for DC voltage measurement
Description
Full BENding
Full Bending Poisson
Full POisson
Half BENding
Half Poisson
QUARter
RTDs
thermocouples
thermistors
Chapter 6