KYMCO UXV 500i Service Manual page 67

Hide thumbs Also See for UXV 500i:
Table of Contents

Advertisement

3
. INSPECTION/ADJUSTMENT
3. Loosen the lock nut and adjuster on the
cable.
4. Turn the adjuster until the caliper lever is
about to rotate then Tighten the lock nut.
Parking brake cable end length:
L: 53 ± 2 mm (2.12 ± 0.08 in)
5. Slowly turn the adjusting bolt on the
caliper clockwise until resistance is felt,
then turn adjusting bolt 1/8
counterclockwise.
6. Tighten the lock nut to the specified
torque while hold the adjusting bolt.
Torque:
1.6 kgf-m (16 N-m, 11.52 lbf-ft)