Toshiba Q9+ Installation & Operation Manual page 96

Adjustable speed drives
Table of Contents

Advertisement

Automatic Function Selection
Program Utilities Display Parameters
This parameter setting is used to configure multiple parameters
with the setting of only one parameter. From the selection below,
multiple parameters may be set as indicated in the table.
Once set, the selected configuration is placed in effect and
remains in effect until this parameter is changed or the individual
settings are changed.
Set this parameter to Disable to set these parameters individu-
ally.
Note: After performing the desired selection, the EOI display
returns to Disabled though the selected function has been
carried out (i.e., without this, if selection 1 is performed,
F004
and
F207
would hold the RR terminal setting
regardless of attempts to change the settings individually).
Settings:
0 — Disabled
1 — RR
2 — V/I
3 — Select RR or V/I by TB (Terminal Board)
4 — Keypad Frequency and Command from TB
5 — Keypad Frequency and Command
6 — Coast Stop
0
Related
Default
Dis-
Params
Settings
abled
Com
Terminal
Mode
Board
F003
Freq
Mode 1
RR
N/C
F004
S3
Preset
Terminal
N/C
Speed 3
F117
Freq
Terminal
Priority
N/C
Board
F200
V/I Setup
0.0%
N/C
F201
Freq
Mode 2
V/I
N/C
F207
Always
Not
On
F110
Assigned
N/C = No Change — the setting remains as it was before setting
parameter F040.
84
F040
Direct Access Parameter Information
Q9 Plus ASD Install/Op Manual
User Selections
1
2
3
4
RR or
Keypad/
RR V/I
V/I via
Freq.
Freq/CMD
TB
CMD/TB
Terminal
N/C
Board
RR N/C
RR
Keypad
Freq.
Ref.
N/C
Priority
Terminal Board
20.0%
N/C
RR
V/I
Keypad
N/C
F100
Direct Access Number —
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No
5
6
Keypad
Coast
Stop
Keypad
N/C
ST
N/C
N/C
N/C
0
https://www.toshiba.com/tic/
F040

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dn-68249-003

Table of Contents