Analog Function Assigned Object 21
Program My Function My Function Analog
This parameter plays a role in the setup of the My Function fea-
ture by selecting the functionality to which the adjustment of
F962
is applied.
Settings:
0 — Disabled (None)
1 — Acceleration Rate
2 — Upper-Limit Frequency
3 — Acceleration Multiplication Factor
4 — Deceleration Multiplication Factor
5 — Manual Torque Boost
6 — Over-Current Stall (F601)
7 — Thermal Protection
8 — Speed Loop Proportional Gain (F460)
9 — Drooping Gain (F320)
10 — PID Proportional Gain (F362)
See the My Function Instruction Manual (P/N E6581335) for a
complete description of the setup requirements and operational
information of the Analog Function Assigned Object parameter.
Monitor Output Function 11
Program My Function My Function Monitor
This parameter plays a role in the setup of the My Function fea-
ture by establishing the function that is to be recorded and out-
put as the Peak, Minimum, or Average value as selected at
parameter F966.
Select the Monitor Display Input Setting number from
page 260
to output the corresponding function.
Use the Communication Number if operating using communica-
tions.
See the My Function Instruction Manual (P/N E6581335) for a
complete description of the setup requirements and operational
information of the Monitor Output Function parameter.
244
F964
Direct Access Parameter Information
Q9 Plus ASD Install/Op Manual
F966
Direct Access Number —
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — No
Direct Access Number —
Parameter Type — Selection List
Factory Default — 2000
Changeable During Run — Yes
Table 14 on
https://www.toshiba.com/tic/
F964
F965

Advertisement