Monitor Output Function 31
Program My Function My Function Monitor
This parameter plays a role in the setup of the My Function fea-
ture by establishing the function that is to be recorded and out-
put as the Peak, Minimum, or Average value as selected at
parameter F970.
Select the Monitor Display Input Setting number from
page 260
to output the corresponding function.
Use the Communication Number if operating using communica-
tions.
See the My Function Instruction Manual (P/N E6581335) for a
complete description of the setup requirements and operational
information of the Monitor Output Function parameter.
Monitor Output Function Command 31
Program My Function My Function Monitor
This parameter plays a role in the setup of the My Function fea-
ture by allowing the user to select the Peak, Minimum, or Normal
(Avg.) value of the parameter
output as a monitored function.
See the My Function Instruction Manual (P/N E6581335) for a
complete description of the setup requirements and operational
information of the Monitor Output Function parameter.
Settings:
0 — Normal
1 — Maximum
2 — Minimum
Monitor Output Function 41
Program My Function My Function Monitor
This parameter plays a role in the setup of the My Function fea-
ture by establishing the function that is to be recorded and out-
put as the Peak, Minimum, or Normal (Avg.) value as selected at
parameter F972.
Select the Monitor Display Input Setting number from
page 260
to output the corresponding function.
Use the Communication Number if operating using communica-
tions.
See the My Function Instruction Manual (P/N E6581335) for a
complete description of the setup requirements and operational
information of the Monitor Output Function parameter.
246
F969
Direct Access Parameter Information
Q9 Plus ASD Install/Op Manual
F969
selection to be recorded and
F972
Direct Access Number —
Parameter Type — Selection List
Factory Default — 2000
Changeable During Run — Yes
Table 14 on
Direct Access Number —
Parameter Type — Selection List
Factory Default — Normal
Changeable During Run — Yes
Direct Access Number —
Parameter Type — Selection List
Factory Default — 2000
Changeable During Run — Yes
Table 14 on
https://www.toshiba.com/tic/
F969
F970
F971