RR Input Point 2 Rate
Program Torque Setpoints
This parameter is used to set the gain and bias of the RR input
terminal when the RR terminal is used as the control input while
operating in the Torque Control mode.
Torque Control is accomplished by establishing an associated V/f
output pattern for a given RR input level.
This parameter sets RR Input Point 2 Rate and is the output
torque value that is associated with the setting of RR Input Point
2 Setting when operating in the Torque Control mode.
This value is entered as 0% to 250% of the rated torque.
See RR Input Point 1 Rate (F214) for additional information on
this parameter.
112
F215
Direct Access Parameter Information
Q9 Plus ASD Install/Op Manual
F216
Direct Access Number —
Parameter Type — Numerical
Factory Default — 100.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.00
Units — %